光明理化学工業株式会社ロゴ
中文 Japanese
Products
RETURN TO TOP OF KITAGAWA Gas Detector Tube.

Simple Measurement Set for Chlorocarbons in Drainage

P-20/P-24AP

■Measurement for solvent concentration is easy by measuring the head space gas with the detector tube.

Image3 Image3
P-20 includes
●Resinous gas collector ●one collecting bottle ●thermometer
P-24AP includes
●AP-20 gas aspirating pump ●five collecting bottles ●thermometer ●carrying case
Detector tube used
Type of harmful chemicals Detector tube used Measuring range after water solvent conversion Drainage criteria
Tetrachloroethylene 135SA 0.14 - 8.20mg/L 0.1mg/L
135SB 0.03 - 0.64mg/L
Trichloroethylene 134SA 0.15 - 8.80mg/L 0.3mg/L
134SB 0.03-1.0mg/L
1,1,1-Trichloroethane 160S 0.67 - 9.00mg/L 3mg/L
Dichloromethane 180S 2.0 - 54.0mg/L 0.2mg/L
1,2-Dichloroethane 230SA 0.3 - 3.7mg/L 0.04mg/L
1,1-Dichloroethylene 132SC 0.01 - 0.27mg/L 1mg/L
cis-1,2-Dichloroethylene 145S 0.1 - 2.7mg/L 0.4mg/L
1,1,2-Trichloroethane 236SA 1.4 - 5.6mg/L 0.06mg/L
1,3-Dichloropropene 132SC 0.02 - 0.50mg/L 0.02mg/L
Carbon tetrachloride 147S 0.1 - 1.0mg/L 0.02mg/L
Benzene 118SC 0.1 - 1.5mg/L 0.1mg/L