| Model | 
				FA-480 | 
			
			
				| Measuring Gas | 
				Combustible gas in the air | 
				Hydrogen in the air | 
				Methane in the air | 
				Organic solvent in the air | 
			
			
				| Detection Principle | 
				Catalytic combustion method (Note 1) | 
				Hot wire semiconductor method (Note 2) | 
				Hot wire semiconductor method | 
				Hot wire semiconductor method | 
			
			
				| Measuring Range | 
				0 - 100%LEL | 
				0 - 2,000ppm | 
				0 - 5,000ppm | 
				0 - 500ppm | 
			
			
				| Accuracy | 
				Within ±25% of the setting value | 
				Within ±25% of the setting value (within a range of 1000ppm from 200ppm) | 
				Within ±25% of the setting value (within a range of 1000ppm from 500ppm) | 
				Within ±25% of the setting value (within a range of 200ppm from 50ppm) | 
			
			
				| Display Method | 
				3-digit LED digital | 
			
			
				| Alarm Method | 
				Red LED lights intermittently and buzzer sounds intermittently | 
			
			
				| Alarm Setting | 
				Adjustable (Standard;25%LEL, 200ppm, 500ppm, 50ppm) | 
			
			
				| Failure display | 
				Red LED lights intermittently and buzzer sounds intermittently | 
			
			
				| Power Source | 
				AC100V±10V, 50/60Hz (AC220V as extra option) | 
			
			
				| Alarm contact output | 
				1a or 1b contact, AC125V, 0.6A (Resistance load) | 
			
			
				| Analog output | 
				4 - 20mA (linear) | 
			
			
				| Detection Point | 
				1 point | 
			
			
				| Operating Temperature Range | 
				Temperature: -10 - 40℃, Humidity: up to 95%RH | 
			
			
				| Installation | 
				Wall mount type (Panel mount type is optional) | 
			
			
				| Dimensions | 
				120(W) x 205(H) x 69(D)mm | 
			
			
				| Weight | 
				0.9kg | 
			
		
		(Note 1) Conformity detector heads for catalytic combustion method : RDE-T, RD-4, RH-S
		(Note 2) Conformity detector heads for hot wire semiconductor method : RDE-TS, RH-S