| Model | 
				OA-480 | 
			
			
				| Measuring Gas | 
				Oxygen | 
			
			
				| Detection Principle | 
				Galvanic cell method | 
			
			
				| Measuring Range | 
				0.0 - 25.0% | 
			
			
				| Accuracy | 
				Within an oxygen concentration of ±1% for the setting value | 
			
			
				| Display Method | 
				3-digit LED digital | 
			
			
				| Alarm Method | 
				Red LED lights intermittently and buzzer sounds intermittently | 
			
			
				| Alarm Setting | 
				Adjustable (Standard;below 18%) | 
			
			
				| Failure display | 
				Red LED lights intermittently and buzzer sounds intermittently | 
			
			
				| Power Source | 
				AC100V±10V, 50/60Hz (AC220V as extra option) | 
			
			
				| Alarm contact output | 
				1a or 1b contact, AC125V, 1A (Resistance load) | 
			
			
				| Analog output | 
				4 - 20mA (linear) | 
			
			
				| Detection Point | 
				1 point | 
			
			
				| Operating Temperature Range | 
				Temperature: -10 - 40℃ | 
			
			
				| Installation | 
				Wall mount type (Panel mount type is optional) | 
			
			
				| Dimensions | 
				120(W)×205(H)×69(D)mm | 
			
			
				| Weight | 
				0.9kg |